虫虫首页| 资源下载| 资源专辑| 精品软件
登录| 注册

safely

  • USB safely remove for USB port.

    USB safely remove for USB port.

    标签: USB safely remove port

    上传时间: 2014-12-01

    上传用户:dongqiangqiang

  • 利用高压看门狗定时器加强汽车安全系统

      Abstract: As electronic systems take over many of the mechanical functions in a car—ranging from engine timing to steering andbraking—there is a growing concern about fault tolerance. There should not be a single point of failure that would prevent a car fromat least "limping" off the road or making it to the nearest service station. Redundant systems, watchdog timers, and other controlcircuits are used to reroute signals and perform other functions that ensure that a vehicle can safely make it off the road when afailure occurs.

    标签: 看门狗定时器 汽车安全系统

    上传时间: 2013-11-10

    上传用户:diets

  • NXP P89LPC901单片机汽车起动保护控制器设计

    在汽车发动机起动时,若发动机起动后起动机不能及时断电,将会烧毁起动机或损坏飞轮齿环;若变速器不在空档位置起动,则起动机的瞬间动力将使汽车位移,还可能引起交通事故和人身安全。为此介绍一种利用NXP P89LPC901单片机控制的汽车起动保护控制器,通过检测汽车起动开关、变速箱档位、发动机转速,实现对汽车发动机起动过程检测和保护。起动保护控制器在发动机起动过程中通过采用逐个关闭打开负载系统,解决汽车发动机过程中因起动电流大而对汽车电源的冲击影响,延长了电瓶寿命。 Abstract:  When the automotive engine is started, the engine start motor and flywheel gear may be damaged, even traffic accidents and personal safeties may be caused by wrong operation or other factors.In order to ensure the automotive engine can be started normally and safely,it is necessary that the protecting measures and methods are considered in the automotive electrical control system.This paper introduces a kind of the automotive engine starting protect controller based on NXP P89LPC901 MCU.The controller can protect the engine starting process by detecting the starter key switch,transmission stall and engine speed.Through the use of close and open load system,the controller can solve the impact on automotive power because of the high-current load in the process of the automobile engine starting, and extend battery life.

    标签: NXP LPC 901 P89

    上传时间: 2013-10-15

    上传用户:mikesering

  • With User Mode Linux you can create virtual Linux machines within a Linux computer and use them to s

    With User Mode Linux you can create virtual Linux machines within a Linux computer and use them to safely test and debug applications, network services, and even kernels. You can try out new distributions, experiment with buggy software, and even test security. Now, for the first time, the creator and maintainer of User Mode Linux shows how to put it to work hands-on. Jeff Dike covers everything from getting started through running enterprise-class User Mode Linux servers. You ll find authoritative advice on bootup, compilation, administration, specialized configurations, and much more.

    标签: Linux computer machines virtual

    上传时间: 2013-12-19

    上传用户:xinzhch

  • Agilent 34401A Service Guide.pdf

    Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. The 34401A may be used to make measurements with the HI and LO inputs connected to mains in such devices, or to the branch outlet itself (up to 300 VAC). However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the protection limits of the 34401A. Note: Voltages above 300 VAC may be measured only in circuits that are isolated from mains. However, transient overvoltages are also present on circuits that are isolated from mains. The Agilent 34401A are designed to safely withstand occasional transient overvoltages up to 2500 Vpk. Do not use this equipment to measure circuits where transient overvoltages could exceed this level. Additional Notices Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see below) indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your local Agilent office, or see www.agilent.com/environment/product for more information. Agilent 34138A Test Lead Set The Agilent 34401A is compatible with the Agilent 34138A Test Lead Set described below. Test Lead Ratings Test Leads - 1000V, 15A Fine Tip Probe Attachments - 300V, 3A Mini Grabber Attachment - 300V, 3A SMT Grabber Attachments - 300V, 3A Operation The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the probe end of the Test Leads. Maintenance If any portion of the Test Lead Set is worn or damaged, do not use. Replace with a new Agilent 3413

    标签: agilent

    上传时间: 2022-02-20

    上传用户: