zemax源码: This DLL models a standard ZEMAX surface type, either plane, sphere, or conic The surface also demonstrates a user-defined apodization filter The filter is defined as part of the real ray trace, case 5 The filter can be used at the stop to produce x-y Gaussian apodization similar to the Gaussian pupil apodization in ZEMAX but separate in x and y. The amplitude apodization is of the form EXP[-(Gx(x/R)^2 + Gy(y/R)^2)] The transmission is of the form EXP[-2(Gx(x/R)^2 + Gy(y/R)^2)] where x^2 + y^2 = r^2 R = semi-diameter The tranmitted intensity is maximum in the center. T is set to 0 if semi-diameter < 1e-10 to avoid division by zero.
标签: standard surface models either
上传时间: 2013-12-05
上传用户:003030
The existence of numerous imaging modalities makes it possible to present different data present in different modalities together thus forming multimodal images. Component images forming multimodal images should be aligned, or registered so that all the data, coming from the different modalities, are displayed in proper locations. The term image registration is most commonly used to denote the process of alignment of images , that is of transforming them to the common coordinate system. This is done by optimizing a similarity measure between the two images. A widely used measure is Mutual Information (MI). This method requires estimating joint histogram of the two images. Experiments are presented that demonstrate the approach. The technique is intensity-based rather than feature-based. As a comparative assessment the performance based on normalized mutual information and cross correlation as metric have also been presented.
标签: present modalities existence different
上传时间: 2017-04-03
上传用户:qunquan
For SunSPOT - Demonstrates how to get temperature sensor readings and display on using LED color/intensity
标签: Demonstrates temperature readings SunSPOT
上传时间: 2014-02-17
上传用户:66666
This application report discusses the design of non-invasive optical plethysmography also called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). The pulsoximeter consists of a peripheral probe combined with the MCU displaying the oxygen saturation and pulse rate on a LCD glass. The same sensor is used for both heart-rate detection and pulsoximetering in this application. The probe is placed on a peripheral point of the body such as a finger tip, ear lobe or the nose. The probe includes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) and the other in the infrared spectrum (940nm). The percentage of oxygen in the body is worked by measuring the intensity from each frequency of light after it transmits through the body and then calculating the ratio between these two intensities.
标签: plethysmography non-invasive application discusses
上传时间: 2014-01-17
上传用户:天诚24