The ISO7220 and ISO7221 are dual-channel digital isolators. To facilitate PCB layout, the channels are orientedin the same direction in the ISO7220 and in opposite directions in the ISO7221. These devices have a logic inputand output buffer separated by TI’s silicon-dioxide (SiO2) isolation barrier, providing galvanic isolation of up to4000 V. Used in conjunction with isolated power supplies, these devices block high voltage, isolate grounds, andprevent noise currents on a data bus or other circuits from entering the local ground and interfering with ordamaging sensitive circuitry.
上传时间: 2013-10-24
上传用户:hbsunhui
The C500 microcontroller family usually provides only one on-chip synchronous serialchannel (SSC). If a second SSC is required, an emulation of the missing interface mayhelp to avoid an external hardware solution with additional electronic components.The solution presented in this paper and in the attached source files emulates the mostimportant SSC functions by using optimized SW routines with a performance up to 25KBaud in Slave Mode with half duplex transmission and an overhead less than 60% atSAB C513 with 12 MHz. Due to the implementation in C this performance is not the limitof the chip. A pure implementation in assembler will result in a strong reduction of theCPU load and therefore increase the maximum speed of the interface. In addition,microcontrollers like the SAB C505 will speed up the interface by a factor of two becauseof an optimized architecture compared with the SAB C513.Moreover, this solution lays stress on using as few on-chip hardware resources aspossible. A more excessive consumption of those resources will result in a highermaximum speed of the emulated interface.Due to the restricted performance of an 8 bit microcontroller a pin compatible solution isprovided only; the internal register based programming interface is replaced by a set ofsubroutine calls.The attached source files also contain a test shell, which demonstrates how to exchangeinformation between an on-chip HW-SSC and the emulated SW-SSC via 5 external wiresin different operation modes. It is based on the SAB C513 (Siemens 8 bit microcontroller).A table with load measurements is presented to give an indication for the fraction of CPUperformance required by software for emulating the SSC.
标签: synchronous Emulating serial
上传时间: 2014-01-31
上传用户:z1191176801
The solution presented in this paper and in the attached source files emulates the mostimportant SSC functions by using SW routines implemented in C. The code is focused onthe SAB C513, but will fit to all C500 derivatives.Beyond the low level software drivers a test shell is delivered. This shell allows a quicktest of the software drivers by an emulator or a starter kit demo board.
上传时间: 2013-11-24
上传用户:363186
基于P87 C591的CAN总线系统智能节点设计Design of CAN System Intelligent Node Based on P87C591 给出了基于带CAN控制器的单片8位微控制器P87C591的智能节点的硬件电路及软件结构,详细介绍了设计中的难点及实现过程中应注意的问题。关键词:CAN总线;智能节点 Abstract:A h ardc ircuita nds oftw arec onfigurationo fth ei ntelligentnode based on a microcontroller with CAN controller P87C591 arepresented.E speciallyt hec ruxi nd esigninga ndt hep roblemst hatshould be paid attention in realizing are discussed in details.Keyw ords:C AN;in telligentn ode CA N 总线 是德国Bosch从20世纪80年代初为解决现代汽车中众多的控制与测试仪器之间的数据交换而开发的一种串行数据通信协议,它是一种多主总线,通信介质可以是双绞线、同轴电缆或光导纤维。由于CAN总线具有较强的纠错能力,支持差分收发,因而适合高噪声环境。并具有较远的传输距离,适用于许多领域的分布式测控系统。目前已在工业自动化、建筑物环境控制、医疗设备等许多领域得到广泛的应用。CAN已成为国际标准化组织IS011898标准。
上传时间: 2013-10-30
上传用户:xymbian
针对使用硬件描述语言进行设计存在的问题,提出一种基于FPGA并采用DSP Builder作为设计工具的数字信号处理器设计方法。并按照Matlab/Simulink/DSP Builder/QuartusⅡ设计流程,设计了一个12阶FIR 低通数字滤波器,通过Quartus 时序仿真及嵌入式逻辑分析仪SignalTapⅡ硬件测试对设计进行了验证。结果表明,所设计的FIR 滤波器功能正确,性能良好。 Abstract: Aiming at the problems in designing DSP using HDL,a method of designing DSP based on FPGA which using DSP Builder as designed tool is pointed out.A 12-order low-pass FIR digital filter was designed according to the process of Matlab/Simulink/DSP Builder/QuartusⅡ, and the design was verified by the timing simulation based on QuartusⅡand practical test based on SignalTapⅡ. The result shows the designed filter is correct in function and good in performance.
上传时间: 2013-11-17
上传用户:lo25643
This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System
上传时间: 2013-11-05
上传用户:维子哥哥
This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System
上传时间: 2013-11-14
上传用户:zoudejile
Accurate measurement of the third order intercept pointfor low distortion IC products such as the LT5514 requirescertain precautions to be observed in the test setup andtesting procedure. The LT5514 linearity performance ishigh enough to push the test equipment and test set-up totheir limits. A method for accurate measurement of thirdorder intermodulation products, IM3, with standard testequipment is outlined below.It is also important to correctly interpret the LT5514specification with respect to ROUT, and the impact ofdemo-board transmission-line termination loss whenevaluating the linearity performance, as explained in theLT5514 Datasheet and in Note 1 of this document.
上传时间: 2013-11-14
上传用户:l254587896
关于NETFLOW信息分析的软件。 is a netflow analyzer. It uses MySQL database to store accounting information. Filters, used in the JFlowAnalyzer, allows very flexible classificate any kind of traffic and store it in the differend fields in database
标签: information accounting analyzer database
上传时间: 2014-01-27
上传用户:kr770906
This book is about the management of business processes. This is certainly not a new topic. Since the beginning of the Industrial Revolution, it has been written about from every possible point of view—economic, sociological, psychological, accountancy, mechanical engineering and business administration. In this book, we examine the management of business processes from the perspective of computing, or—to put it more broadly—of information technology. The reason is that information technology has made huge leaps forward in recent years, resulting in the creation of completely new ways of organizing business processes. The development of generic software packages for managing business processes—so-called workflow management systems (WFMS)—is particularly important in this respect.
标签: This management certainly processes
上传时间: 2013-11-29
上传用户:shus521