虫虫首页| 资源下载| 资源专辑| 精品软件
登录| 注册

Probe

  • Probe PCI devices, and compare information with standard file

    Probe PCI devices, and compare information with standard file

    标签: information standard devices compare

    上传时间: 2014-01-07

    上传用户:zhuimenghuadie

  • Probe方式的1341驱动

    Probe方式的1341驱动,在2.6.11内核测试

    标签: Probe 1341 方式 驱动

    上传时间: 2013-12-25

    上传用户:franktu

  • Lambda Probe(Tomcat Probe)是一个基于Web以实时的方式来管理单个Tomcat主机的工具。它除了具备标准Tomcat Manager大部份功能之外还提供一些能够帮助Web开发者

    Lambda Probe(Tomcat Probe)是一个基于Web以实时的方式来管理单个Tomcat主机的工具。它除了具备标准Tomcat Manager大部份功能之外还提供一些能够帮助Web开发者和系统管理员更加清楚地了解Tomcat运行情况的功能。Tomcat Probe采用XHTML1.0与CSS 2.0技术进行开发所以界面非常好看,操作很方便。

    标签: Tomcat Probe Web Manager

    上传时间: 2013-12-21

    上传用户:aeiouetla

  • Design of a Microwave Probe Fed Rectangular Micro‐strip Patch Antenna

    Design of a Microwave Probe Fed Rectangular Micro‐strip Patch Antenna

    标签: Rectangular Microwave Antenna Design

    上传时间: 2017-09-09

    上传用户:colinal

  • ARM-Linux-IIC设备的添加与驱动实现

        本文分析了ARM-Linux下IIC总线及其设备驱动的层次结构,指出了IIC设备添加与驱动实现的途径,详细阐述了如何采用通用i2c-dev.c驱动常规IIC设备、如何编写特定IIC设备的Probe方式驱动、怎样设计动态加载的简易IIC“客服-驱动”、怎样使用GPIO模拟IIC总线快速驱动设备等常用具体实现过程和关键环节,并说明了这些方法的优势和不足。   

    标签: ARM-Linux-IIC 设备 驱动实现

    上传时间: 2013-10-13

    上传用户:xingisme

  • A Single-Chip Pulsoximeter Des

    This application report discusses the design of non-invasive optical plethysmographyalso called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). Thepulsoximeter consists of a peripheral Probe combined with the MCU displaying theoxygen saturation and pulse rate on a LCD glass. The same sensor is used for bothheart-rate detection and pulsoximetering in this application. The Probe is placed on aperipheral point of the body such as a finger tip, ear lobe or the nose. The Probeincludes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) andthe other in the infrared spectrum (940nm). The percentage of oxygen in the body isworked by measuring the intensity from each frequency of light after it transmitsthrough the body and then calculating the ratio between these two intensities.

    标签: Pulsoximeter Single-Chip Des

    上传时间: 2013-10-27

    上传用户:黑漆漆

  • 1

    1, SPI_877A,是针对Probe877A所写。 SPI_877,是针对Probe877所写。 SPI_77,是针对Probe77所写。 初次使用使用PICMATE2004或者其简化版精灵版,如果为以上提到的3款型号,并有TPDEM1, 请根据Probe型号在相应文件夹下打开项目,编译,并运行,具体连线请看各文件夹说明。 2, 其它文件夹项目均针对Probe877A所建立,如果要使用Probe877,请修改头文件,并选择Probe877支持的芯片。 3, 严格禁止将Probe877与877A混用,否则将造成仿真芯片工作异常。

    标签:

    上传时间: 2013-12-21

    上传用户:lz4v4

  • The VISA Probes for LabVIEW 7.0 greatly extend the amount of relevant information displayed when us

    The VISA Probes for LabVIEW 7.0 greatly extend the amount of relevant information displayed when using LabVIEW Probes on VISA refnums. They are used automatically by LabVIEW in place of the generic Probe when they are installed.

    标签: information displayed relevant LabVIEW

    上传时间: 2013-12-17

    上传用户:rocwangdp

  • This application report discusses the design of non-invasive optical plethysmography also called as

    This application report discusses the design of non-invasive optical plethysmography also called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). The pulsoximeter consists of a peripheral Probe combined with the MCU displaying the oxygen saturation and pulse rate on a LCD glass. The same sensor is used for both heart-rate detection and pulsoximetering in this application. The Probe is placed on a peripheral point of the body such as a finger tip, ear lobe or the nose. The Probe includes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) and the other in the infrared spectrum (940nm). The percentage of oxygen in the body is worked by measuring the intensity from each frequency of light after it transmits through the body and then calculating the ratio between these two intensities.

    标签: plethysmography non-invasive application discusses

    上传时间: 2014-01-17

    上传用户:天诚24

  • Agilent 34401A Service Guide.pdf

    Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. The 34401A may be used to make measurements with the HI and LO inputs connected to mains in such devices, or to the branch outlet itself (up to 300 VAC). However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the protection limits of the 34401A. Note: Voltages above 300 VAC may be measured only in circuits that are isolated from mains. However, transient overvoltages are also present on circuits that are isolated from mains. The Agilent 34401A are designed to safely withstand occasional transient overvoltages up to 2500 Vpk. Do not use this equipment to measure circuits where transient overvoltages could exceed this level. Additional Notices Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see below) indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your local Agilent office, or see www.agilent.com/environment/product for more information. Agilent 34138A Test Lead Set The Agilent 34401A is compatible with the Agilent 34138A Test Lead Set described below. Test Lead Ratings Test Leads - 1000V, 15A Fine Tip Probe Attachments - 300V, 3A Mini Grabber Attachment - 300V, 3A SMT Grabber Attachments - 300V, 3A Operation The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the Probe end of the Test Leads. Maintenance If any portion of the Test Lead Set is worn or damaged, do not use. Replace with a new Agilent 3413

    标签: agilent

    上传时间: 2022-02-20

    上传用户:zinuoyu