虫虫首页| 资源下载| 资源专辑| 精品软件
登录| 注册

Logging-related

  • dsPIC30F产品手册

    dsPIC30F产品手册 High Performance Digital Signal Controllers This section of the manual contains the following topics:1.1 Introduction 1.2 Manual Objective 1.3 Device Structure1.4 Development Support  1.5 Style and Symbol Conventions 1.6 Related Documents 1.7 Revision History

    标签: dsPIC 30F 30 产品手册

    上传时间: 2013-12-26

    上传用户:xzt

  • TPS65930 TPS65920与OMAP3530硬件连接

    This document describes the system hardware implementation for the OMAP3530 processor and theTPS65930/20 companion power integrated circuit (IC). The document concentrates on the powerconnectivity for the processor and the companion power IC. The document also briefly explains someother specifics related to power, such as the boot modes and the power-up sequence.

    标签: TPS 65930 65920 3530

    上传时间: 2013-11-14

    上传用户:yeling1919

  • PCA82C250 PCA82C251 CAN Transc

    The PCA82C250 and PCA82C251 are advanced transceiver products for use in automotive and general industrialapplications with transfer rates up to 1 Mbit/s. They support the differential bus signal representation beingdescribed in the international standard for in-vehicle CAN high-speed applications (ISO 11898). Controller AreaNetwork (CAN) is a serial bus protocol being primarily intended for transmission of control related data between anumber of bus nodes.

    标签: PCA 82C Transc 82

    上传时间: 2013-11-24

    上传用户:Alick

  • 一款监视串口和并口使用的小软件.

    (Portmon is an application that lets you monitor serial and parallel activity on your local system, or any computer on the network that you can reach via TCP/IP. It is the most powerful tool available for tracking down port-related configuration problems and analyzing application port usage.)

    标签: 监视 串口 并口 软件

    上传时间: 2013-11-07

    上传用户:1412904892

  • 采用TÜV认证的FPGA开发功能安全系统

    This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System

    标签: FPGA 安全系统

    上传时间: 2013-11-05

    上传用户:维子哥哥

  • 微电脑型交流电流异常警报电表

    特点 精确度0.25%滿刻度 ±1位數 输入配线系统可任意选择 CT比可任意设定 具有异常电流值与异常次数记录保留功能 电流过高或过低检测可任意设定 报警继电器复归方式可任意設定 尺寸小,穩定性高 2.主要規格 辅助电源: AC110V&220V ±20%(50 or 60Hz) AC220V&440V ±20%(50 or 60Hz)(optional) 精确度: 0.25% F.S. ±1 digit 输入负载: <0.2VA (Current) 最大过载能力 : Current related input: 2 x rated continuous 10 x rated 30 sec. 25 x rated 3sec. 50 x rated 1 sec. 输入电流范围: AC0-5A (10-1000Hz) CT ratio : 1-2000 adjustable 启动延迟动作时间: 0-99.9 second adjustable 继电器延迟动作时间: 0-99.9 second adjustable 继电器复归方式: Manual (N) / latch(L) can be modified 继电器磁滞范围: 0-999 digit adjustable 继电器动作方向: HI /LO/GO/HL can be modified 继电器容量: AC 250V-5A, DC 30V-7A 过载显示: "doFL" 温度系数: 50ppm/℃ (0-50℃) 显示幕: Red high efficiency LEDs high 14.22mm(.56")(PV) Red high efficiency LEDs high 14.22mm(.276")(NO) 参数设定方式: Touch switches 记忆型式 : Non-volatile E2PROM memory 绝缘耐压能力: 2KVac/1 min. (input/output/power) 1600Vdc(input/output 使用环境条件 : 0-50℃(20 to 90% RH non-condensed) 存放环境条件: 0-70℃(20 to 90% RH non-condensed) CE认证: EN 55022:1998/A1:2000 Class A EN 61000-3-2:2000 EN 61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001

    标签: 微电脑 交流电流 警报电表

    上传时间: 2013-10-14

    上传用户:wanghui2438

  • 针对Xilinx FPGA的电源解决方案

    Abstract: Field-programmable gate arrays (FPGAs) are used in a wide variety of applications and end markets, including digital signalprocessing, medical imaging, and high-performance computing. This application note outlines the issues related to powering FPGAs.It also discusses Maxim's solutions for powering Xilinx® FPGAs.

    标签: Xilinx FPGA 电源解决方案

    上传时间: 2013-12-16

    上传用户:haohaoxuexi

  • 光纤_dB_衰减和测量介绍

    This document is a quick reference to some of the formulas and important information related to optical technologies. It focuses on decibels (dB), decibels per milliwatt (dBm), attenuation and measurements, and provides an introduction to optical fibers.

    标签: dB 光纤 衰减 测量

    上传时间: 2013-10-17

    上传用户:libenshu01

  • 采用TÜV认证的FPGA开发功能安全系统

    This white paper discusses how market trends, the need for increased productivity, and new legislation have accelerated the use of safety systems in industrial machinery. This TÜV-qualified FPGA design methodology is changing the paradigms of safety designs and will greatly reduce development effort, system complexity, and time to market. This allows FPGA users to design their own customized safety controllers and provides a significant competitive advantage over traditional microcontroller or ASIC-based designs. Introduction The basic motivation of deploying functional safety systems is to ensure safe operation as well as safe behavior in cases of failure. Examples of functional safety systems include train brakes, proximity sensors for hazardous areas around machines such as fast-moving robots, and distributed control systems in process automation equipment such as those used in petrochemical plants. The International Electrotechnical Commission’s standard, IEC 61508: “Functional safety of electrical/electronic/programmable electronic safety-related systems,” is understood as the standard for designing safety systems for electrical, electronic, and programmable electronic (E/E/PE) equipment. This standard was developed in the mid-1980s and has been revised several times to cover the technical advances in various industries. In addition, derivative standards have been developed for specific markets and applications that prescribe the particular requirements on functional safety systems in these industry applications. Example applications include process automation (IEC 61511), machine automation (IEC 62061), transportation (railway EN 50128), medical (IEC 62304), automotive (ISO 26262), power generation, distribution, and transportation. 图Figure 1. Local Safety System

    标签: FPGA 安全系统

    上传时间: 2013-11-14

    上传用户:zoudejile

  • Nios II软件开发人员手册中的缓存和紧耦合存储器部分

            Nios II 软件开发人员手册中的缓存和紧耦合存储器部分 Nios® II embedded processor cores can contain instruction and data caches. This chapter discusses cache-related issues that you need to consider to guarantee that your program executes correctly on the Nios II processor. Fortunately, most software based on the Nios II hardware abstraction layer (HAL) works correctly without any special accommodations for caches. However, some software must manage the cache directly. For code that needs direct control over the cache, the Nios II architecture provides facilities to perform the following actions:

    标签: Nios 软件开发 存储器

    上传时间: 2013-10-25

    上传用户:虫虫虫虫虫虫