Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. The 34401A may be used to make measurements with the HI and LO inputs connected to mains in such devices, or to the branch outlet itself (up to 300 VAC). However, the 34401A may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently wired motors. Such devices and circuits are subject to overvoltages that may exceed the protection limits of the 34401A. Note: Voltages above 300 VAC may be measured only in circuits that are isolated from mains. However, transient overvoltages are also present on circuits that are isolated from mains. The Agilent 34401A are designed to safely withstand occasional transient overvoltages up to 2500 Vpk. Do not use this equipment to measure circuits where transient overvoltages could exceed this level. Additional Notices Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This product complies with the WEEE Directive (2002/96/EC) marking requirement. The affixed product label (see beLOw) indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a "Monitoring and Control instrumentation" product. Do not dispose in domestic household waste. To return unwanted products, contact your LOcal Agilent office, or see www.agilent.com/environment/product for more information. Agilent 34138A Test Lead Set The Agilent 34401A is compatible with the Agilent 34138A Test Lead Set described beLOw. Test Lead Ratings Test Leads - 1000V, 15A Fine Tip Probe Attachments - 300V, 3A Mini Grabber Attachment - 300V, 3A SMT Grabber Attachments - 300V, 3A Operation The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the probe end of the Test Leads. Maintenance If any portion of the Test Lead Set is worn or damaged, do not use. Replace with a new Agilent 3413
标签: agilent
上传时间: 2022-02-20
上传用户:
好吧,电路很简单,可是元件值如何选?射频器件差一点就差很多,是不是一定要用专用的射频元件?做为常温测试来说,普通器件就可以满足,当然,如果要考虑温度、谐波、灵敏度等,电感还是选用高Q的,电容选择COG材质的。看看PA元件如何选,AN435里写得很清楚。不想看原理的可以直接参考其值:按以上参考值出17-19dBm是可以的,但是要满打满的出到20dBm,或者大于20dBm则需要根据板子微调部分元件,在你不知道如果调试时,可以小范围调整一下CM以及天线开关后面的低通滤波器,如果还是不行,那就调电感吧。不想深究的可以跳过本节了,下面是AN435里对于PA匹配的原理性说明,感兴趣的可以继续往下面看,其实Sl4432的硬件手册里说得是很全的,多看手册可以学到很多。Sl4432内部的PA并非传统的A,B,C类放大器,也不是D类,而是E类放大器,其实就是一个开关而已。下图是AN435里一个开关类射频放大器的结构图。这个放大器理解起来很容易,比传统ABC类放大器容易多了。其中Lchoke为上拉电感,与三极管C极的电阻是一样的作用,在S0开关时,会给Cshunt充电,经过CO和LO组成的带通滤器器,滤除开关过程中产生的杂波及谐波,再经过Lx就可以得到一个正弦波。这类放大器只是提供一个方波,再通过LC选频。
上传时间: 2022-07-03
上传用户:bluedrops