The LTM8020, LTM8021, LTM8022 and LTM8023 μModule®regulators are complete easy-to-use encapsulated stepdownDC/DC regulators intended to take the pain and aggravationout of implementing a switching power supplyonto a system board. With a μModule regulator, you onlyneed an input cap, output cap and one or two resistorsto complete the design. As one might imagine, this highlevel of integration greatly simplifi es the task of printedcircuit board design, reducing the effort to four categories:component footprint generation, component placement,routing the nets, and thermal vias.
上传时间: 2014-01-18
上传用户:laomv123
When a system designer specifies a nonisolated dc/dc powermodule, considering the needed input voltage range isequally as important as considering the required performanceattributes and features. Generally, nonisolated moduleshave either a narrow or a wide input voltage range. Narrowinputmodules typically have a nominal input voltage of3.3, 5, or 12 V. For systems that operate from a tightlyregulated input bus—such as those that do not use batterybackup—a narrow-input module is often adequate sincethe input remains fairly stable.Offering greater flexibility, wide-input modules operatewithin a range of 7 to 36 V, which includes the popular12- or 24-V industrial bus. This enables a single module tobe used for generating multiple voltages. These modulesare ideal for industrial controls, HVAC systems, vehicles,medical instrumentation, and other applications that usea loosely regulated distribution bus. In addition, systemspowered by a rectifier/battery charger with lead-acidbattery backup almost always require wide-input modules.System designers who choose power supplies may wantto take a close look at the latest generation of wide-inputdc/dc modules.
标签: Wide-input modules offer dc
上传时间: 2014-12-24
上传用户:dragonhaixm
Features: High efficiency, high reliability, low cost AC input range selected by switch 100% full load burn-in test Protections: Short circuit / Over load Fixed switching frequency at 25KHz Cooling by free air convection 1 year warranty Dimensions: 199*98*38mm (L*W*H)
标签: Switchin Output Single SKS
上传时间: 2013-10-30
上传用户:taa123456
Analog Inputs and Outputs in an S7 PLC are represented in the PLC as a 16-bit integer. Over the nominal span of the analog input or output, the value of this integer will range between - 27648 and +27648. However, it is easier to use the analog values if they are scaled to the same units and ranges as the process being controlled. This applications tip describes methods for scaling analog values to and from engineering units.
上传时间: 2013-11-17
上传用户:3294322651
要搞清楚单片机与PLC的异同,首先得明确什幺是单片机,什幺是PLC。对此,我们简要回顾一下计算机的发展历程也许有帮助,按计算机专家的原始定义,计算机系统由五大部分--即控制单元(CU)、算术运算单元(ALU)、存储器(Memory)、输入设备(Input)、输出设备(Output)组成。早期计算机(晶体管的或集成电路的,不包括电子管的)的CU或ALU由一块甚至多块电路板组成,CU和ALU是分离的,随着集成度的提高,CU和ALU合在一块就组成了中央处理单元(CPU),接着将CPU集成到单块集成电路中就产生MPU或MCU,出现了如Intel4004、8008、8080,8085、8086、8088、Z80等MPU。此后,MPU的发展产生了两条分支,一支往高性能、高速度、大容量方向发展,典型芯片如:Intel80186、286、386、486、586、P2、P3、P4等,速度从4.7MHz到现在的3.2GHz。另一支则往多功能方向发展,将存储器(ROM、PROM、EPROM、EEPROM、FLASHROM、SRAM等)、输入/出接口(Timer/Counter、PWM、ADC/DAC、UART、IIC、SPI、RTC、PCA、FPGA等)全部集成在一块集成电路中而成为SOC。依愚之见,这就是当今广泛应用的单片计算机,简称单片机。这一分支可谓品种繁多,位宽从8位到32位,引脚数从6个到几百个,工作频率从几十KHz到几百MHz,体系结构既有CISC也有RISC,数不胜数。常用的有MCS-51系列、MCS-96系列、PIC系列、AVR系列、ARM7/9系列、TMS320系列、MSP430系列、MOTOROLA众多的单片机等等。
上传时间: 2013-10-16
上传用户:jjj0202
FEATURES400 MSPS internal clock speedIntegrated 10-bit DAC32-bit tuning wordPhase noise ≤ –120 dBc/Hz @ 1 kHz offset (DAC output)Excellent dynamic performance>75 dB SFDR @ 160 MHz (±100 kHz offset) AOUTSerial I/O control1.8 V power supplySoftware and hardware controlled power-down48-lead TQFP/EP packageSupport for 5 V input levels on most digital inputsPLL REFCLK multiplier (4× to 20×)Internal oscillator; can be driven by a single crystalPhase modulation capabilityMultichip synchronization
上传时间: 2014-12-04
上传用户:axin881314
The CAT25128 is a 128−Kb Serial CMOS EEPROM device internally organized as 16Kx8 bits. This features a 64−byte page write buffer and supports the Serial Peripheral Interface (SPI) protocol. The device is enabled through a Chip Select (CS) input. In addition, the required bus signals are clock input (SCK), data input (SI) and data output (SO) lines. The HOLD input may be used to pause any serial communication with the CAT25128 device. The device featuressoftware and hardware write protection, including partial as well as full array protection.
上传时间: 2013-11-15
上传用户:fklinran
The ISO7220 and ISO7221 are dual-channel digital isolators. To facilitate PCB layout, the channels are orientedin the same direction in the ISO7220 and in opposite directions in the ISO7221. These devices have a logic inputand output buffer separated by TI’s silicon-dioxide (SiO2) isolation barrier, providing galvanic isolation of up to4000 V. Used in conjunction with isolated power supplies, these devices block high voltage, isolate grounds, andprevent noise currents on a data bus or other circuits from entering the local ground and interfering with ordamaging sensitive circuitry.
上传时间: 2013-10-24
上传用户:hbsunhui
The Philips family of Multiplexers and Switches consists of bi-directional translating switches controlled via the I2C or SMBus to fan out an upstream SCL/SDA pair to 2, 4 or 8 downstream channels of SCx/SDx pairs. The Multiplexers allow only one downstream channel to be selected at a time, while the Switches allow any individual downstream channel or combination of downstream channels to be selected, depending on the content of the programmable control register. Once one or several channels have been selected, the device acts as a wire, allowing the master on the upstream channel to send commands to devices on all the active downstream channels, and devices on the active downstream channels to communicate with each other and the master. External pull-up resistors are used to pull each individual channel up to the desired voltage level. Combined interrupt output and hardware reset input are device options that are featured.
上传时间: 2013-10-11
上传用户:dianxin61
The P82B96 offers many different ways in which it can be used as abus interface. In its simplest application it can be used as aninterface between bus systems operating from different supplyvoltages. Opto isolation between two bus systems is possible, andalso the availability of the Tx and Rx signals permits interfacing ofthe P82B96 with other bus systems which separate the forwardoutput path, from the backward input signal path.
上传时间: 2013-10-11
上传用户:洛木卓